>{version:2,variables:['$window','$usable','$load','$need'] }

`Autonomia ed energia della power station`{fontSize:24,bold:true,width:460}

#1000{label:'Energia nom.',quantity:{unit:'energy.watt_hour'}}*(90{label:'Inizio'}%-{}10{label:'Riserva'}%)=?{label:'Energia finestra',varId:'$window',quantity:{target:'energy.watt_hour'}};

#?{varId:'$window'}*85{label:'Quota utile'}%=?{label:'Energia utile',varId:'$usable',quantity:{target:'energy.watt_hour'}};

#60{label:'Carico A',quantity:{unit:'power.watt'}}+10{label:'Carico B',quantity:{unit:'power.watt'}}=?{label:'Carico totale',varId:'$load',quantity:{target:'power.watt'}};

#?{varId:'$usable'}/?{varId:'$load'}=?{label:'Autonomia',quantity:{target:'time.hour'}};

#?{varId:'$load'}*8{label:'Durata',quantity:{unit:'time.hour'}}=?{label:'Fabbisogno',varId:'$need',quantity:{target:'energy.watt_hour'}};

#?{varId:'$usable'}-{}?{varId:'$need'}=?{label:'Saldo energia',quantity:{target:'energy.watt_hour'}};

`Usa la potenza media del periodo.\nLa quota utile è un’ipotesi scelta.\nEnergia sufficiente non prova la compatibilità delle uscite.`{width:460}